{"id":1204,"date":"2022-08-27T11:28:48","date_gmt":"2022-08-27T07:58:48","guid":{"rendered":"https:\/\/delta-gas.com\/continuous-emission-monitoring-systems-cems\/"},"modified":"2025-09-27T17:01:42","modified_gmt":"2025-09-27T13:31:42","slug":"paysh-modavam-alayandeh-cems","status":"publish","type":"page","link":"https:\/\/delta-gas.com\/fa\/paysh-modavam-alayandeh-cems\/","title":{"rendered":"\u0633\u06cc\u0633\u062a\u0645\u200c\u0647\u0627\u06cc \u067e\u0627\u06cc\u0634 \u0645\u062f\u0627\u0648\u0645 \u0622\u0644\u0627\u06cc\u0646\u062f\u0647\u200c\u0647\u0627 (CEMS)"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<p>Continuous emission monitoring systems (CEMS) were historically used as a tool to monitor flue gas for oxygen, carbon monoxide and carbon dioxide to provide information for combustion control in industrials. They are currently used as a means to comply with IDOE(Iran Department of Environment) air emission standards or the European Environmental Protection Agency, other federal emission programs, or state permitted emission standards. Facilities employ the use of CEMS to continuously collect record and report the required emissions data. The standard CEM system consists of a sample probe, filter, sample line, gas conditioning system, calibration gas system, and a series of gas analyzers which reflect the parameters being monitored. Typical monitored emissions include: sulfur dioxide (SO2), nitrogen oxides (NO), carbon monoxide (CO), carbon dioxide (CO2), hydrogen chloride (HCL), airborne particulate matter (Dust), mercury (Hg), volatile organic compounds (VOC), and oxygen (O2). CEM systems can also measure air flow, flue gas opacity and moisture. All gas components should be monitor and measure based on PPM or mg\/m3 unit. Particles and dust should be measure based on mg\/Nm3 and it shall report by means of total dust value. The best system is one that (1) works in the plant application, (2) can be purchased and operate at \u201creasonable cost\u201d, and (3)requires relatively low maintenance.        <\/p>\n","protected":false},"author":1,"featured_media":622,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1204","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v23.1 (Yoast SEO v27.3) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Continuous Emission Monitoring Systems (CEMS) | Delta Gas Mobin<\/title>\n<meta name=\"description\" content=\"Delta Gas Mobin provides advanced CEMS solutions for real-time monitoring of emissions such as SO\u2082, NO\u2093, CO, CO\u2082, and particulate matter, ensuring compliance with environmental regulations and optimizing industrial processes.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/delta-gas.com\/continuous-emission-monitoring-systems-cems\/\" \/>\n<meta property=\"og:locale\" content=\"fa_IR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u0633\u06cc\u0633\u062a\u0645 \u0647\u0627\u06cc \u0646\u0638\u0627\u0631\u062a \u0628\u0631 \u0627\u0646\u062a\u0634\u0627\u0631\" \/>\n<meta property=\"og:description\" content=\"Delta Gas Mobin Group delivers state-of-the-art Continuous Emission Monitoring Systems (CEMS) to measure critical pollutants like SO\u2082, NO\u2093, CO, CO\u2082, HCl, VOCs, mercury, and particulate matter. Utilizing technologies such as NDIR, NDUV, Gas Chromatography, Paramagnetic, and Chemiluminescence, our systems provide precise, real-time emission data to support regulatory compliance, process optimization, and energy efficiency across industries including power plants, refineries, petrochemical facilities, and more\" \/>\n<meta property=\"og:url\" content=\"https:\/\/delta-gas.com\/continuous-emission-monitoring-systems-cems\/\" \/>\n<meta property=\"og:site_name\" content=\"Delta Gas Mobin Group\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-27T13:31:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/delta-gas.com\/wp-content\/uploads\/2022\/08\/EMISSION-570x300-1.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"\u0633\u06cc\u0633\u062a\u0645 \u0647\u0627\u06cc \u0646\u0638\u0627\u0631\u062a \u0628\u0631 \u0627\u0646\u062a\u0634\u0627\u0631\" \/>\n<meta name=\"twitter:description\" content=\"Delta Gas Mobin Group delivers state-of-the-art Continuous Emission Monitoring Systems (CEMS) to measure critical pollutants like SO\u2082, NO\u2093, CO, CO\u2082, HCl, VOCs, mercury, and particulate matter. Utilizing technologies such as NDIR, NDUV, Gas Chromatography, Paramagnetic, and Chemiluminescence, our systems provide precise, real-time emission data to support regulatory compliance, process optimization, and energy efficiency across industries including power plants, refineries, petrochemical facilities, and more\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/delta-gas.com\/wp-content\/uploads\/2022\/08\/EMISSION-570x300-1.jpg\" \/>\n<meta name=\"twitter:label1\" content=\"\u0632\u0645\u0627\u0646 \u062a\u0642\u0631\u06cc\u0628\u06cc \u0628\u0631\u0627\u06cc \u062e\u0648\u0627\u0646\u062f\u0646\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 \u062f\u0642\u06cc\u0642\u0647\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/delta-gas.com\\\/continuous-emission-monitoring-systems-cems\\\/\",\"url\":\"https:\\\/\\\/delta-gas.com\\\/continuous-emission-monitoring-systems-cems\\\/\",\"name\":\"Continuous Emission Monitoring Systems (CEMS) | Delta Gas Mobin\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/delta-gas.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/delta-gas.com\\\/continuous-emission-monitoring-systems-cems\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/delta-gas.com\\\/continuous-emission-monitoring-systems-cems\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/delta-gas.com\\\/wp-content\\\/uploads\\\/2022\\\/08\\\/EMISSION-570x300-1.jpg\",\"datePublished\":\"2022-08-27T07:58:48+00:00\",\"dateModified\":\"2025-09-27T13:31:42+00:00\",\"description\":\"Delta Gas Mobin provides advanced CEMS solutions for real-time monitoring of emissions such as SO\u2082, NO\u2093, CO, CO\u2082, and particulate matter, ensuring compliance with environmental regulations and optimizing industrial processes.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/delta-gas.com\\\/continuous-emission-monitoring-systems-cems\\\/#breadcrumb\"},\"inLanguage\":\"fa-IR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/delta-gas.com\\\/continuous-emission-monitoring-systems-cems\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fa-IR\",\"@id\":\"https:\\\/\\\/delta-gas.com\\\/continuous-emission-monitoring-systems-cems\\\/#primaryimage\",\"url\":\"https:\\\/\\\/delta-gas.com\\\/wp-content\\\/uploads\\\/2022\\\/08\\\/EMISSION-570x300-1.jpg\",\"contentUrl\":\"https:\\\/\\\/delta-gas.com\\\/wp-content\\\/uploads\\\/2022\\\/08\\\/EMISSION-570x300-1.jpg\",\"width\":570,\"height\":300},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/delta-gas.com\\\/continuous-emission-monitoring-systems-cems\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/delta-gas.com\\\/fa\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u0633\u06cc\u0633\u062a\u0645\u200c\u0647\u0627\u06cc \u067e\u0627\u06cc\u0634 \u0645\u062f\u0627\u0648\u0645 \u0622\u0644\u0627\u06cc\u0646\u062f\u0647\u200c\u0647\u0627 (CEMS)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/delta-gas.com\\\/#website\",\"url\":\"https:\\\/\\\/delta-gas.com\\\/\",\"name\":\"Delta Gas Mobin Group\",\"description\":\"Delta Gas Mobin Group is established in 2010 and recognized today as one of the\",\"publisher\":{\"@id\":\"https:\\\/\\\/delta-gas.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/delta-gas.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fa-IR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/delta-gas.com\\\/#organization\",\"name\":\"Delta Gas Mobin Group\",\"url\":\"https:\\\/\\\/delta-gas.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fa-IR\",\"@id\":\"https:\\\/\\\/delta-gas.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/delta-gas.com\\\/wp-content\\\/uploads\\\/2022\\\/08\\\/Delta-gas22.png\",\"contentUrl\":\"https:\\\/\\\/delta-gas.com\\\/wp-content\\\/uploads\\\/2022\\\/08\\\/Delta-gas22.png\",\"width\":150,\"height\":45,\"caption\":\"Delta Gas Mobin Group\"},\"image\":{\"@id\":\"https:\\\/\\\/delta-gas.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Continuous Emission Monitoring Systems (CEMS) | Delta Gas Mobin","description":"Delta Gas Mobin provides advanced CEMS solutions for real-time monitoring of emissions such as SO\u2082, NO\u2093, CO, CO\u2082, and particulate matter, ensuring compliance with environmental regulations and optimizing industrial processes.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/delta-gas.com\/continuous-emission-monitoring-systems-cems\/","og_locale":"fa_IR","og_type":"article","og_title":"\u0633\u06cc\u0633\u062a\u0645 \u0647\u0627\u06cc \u0646\u0638\u0627\u0631\u062a \u0628\u0631 \u0627\u0646\u062a\u0634\u0627\u0631","og_description":"Delta Gas Mobin Group delivers state-of-the-art Continuous Emission Monitoring Systems (CEMS) to measure critical pollutants like SO\u2082, NO\u2093, CO, CO\u2082, HCl, VOCs, mercury, and particulate matter. Utilizing technologies such as NDIR, NDUV, Gas Chromatography, Paramagnetic, and Chemiluminescence, our systems provide precise, real-time emission data to support regulatory compliance, process optimization, and energy efficiency across industries including power plants, refineries, petrochemical facilities, and more","og_url":"https:\/\/delta-gas.com\/continuous-emission-monitoring-systems-cems\/","og_site_name":"Delta Gas Mobin Group","article_modified_time":"2025-09-27T13:31:42+00:00","og_image":[{"url":"https:\/\/delta-gas.com\/wp-content\/uploads\/2022\/08\/EMISSION-570x300-1.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_title":"\u0633\u06cc\u0633\u062a\u0645 \u0647\u0627\u06cc \u0646\u0638\u0627\u0631\u062a \u0628\u0631 \u0627\u0646\u062a\u0634\u0627\u0631","twitter_description":"Delta Gas Mobin Group delivers state-of-the-art Continuous Emission Monitoring Systems (CEMS) to measure critical pollutants like SO\u2082, NO\u2093, CO, CO\u2082, HCl, VOCs, mercury, and particulate matter. Utilizing technologies such as NDIR, NDUV, Gas Chromatography, Paramagnetic, and Chemiluminescence, our systems provide precise, real-time emission data to support regulatory compliance, process optimization, and energy efficiency across industries including power plants, refineries, petrochemical facilities, and more","twitter_image":"https:\/\/delta-gas.com\/wp-content\/uploads\/2022\/08\/EMISSION-570x300-1.jpg","twitter_misc":{"\u0632\u0645\u0627\u0646 \u062a\u0642\u0631\u06cc\u0628\u06cc \u0628\u0631\u0627\u06cc \u062e\u0648\u0627\u0646\u062f\u0646":"1 \u062f\u0642\u06cc\u0642\u0647"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/delta-gas.com\/continuous-emission-monitoring-systems-cems\/","url":"https:\/\/delta-gas.com\/continuous-emission-monitoring-systems-cems\/","name":"Continuous Emission Monitoring Systems (CEMS) | Delta Gas Mobin","isPartOf":{"@id":"https:\/\/delta-gas.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/delta-gas.com\/continuous-emission-monitoring-systems-cems\/#primaryimage"},"image":{"@id":"https:\/\/delta-gas.com\/continuous-emission-monitoring-systems-cems\/#primaryimage"},"thumbnailUrl":"https:\/\/delta-gas.com\/wp-content\/uploads\/2022\/08\/EMISSION-570x300-1.jpg","datePublished":"2022-08-27T07:58:48+00:00","dateModified":"2025-09-27T13:31:42+00:00","description":"Delta Gas Mobin provides advanced CEMS solutions for real-time monitoring of emissions such as SO\u2082, NO\u2093, CO, CO\u2082, and particulate matter, ensuring compliance with environmental regulations and optimizing industrial processes.","breadcrumb":{"@id":"https:\/\/delta-gas.com\/continuous-emission-monitoring-systems-cems\/#breadcrumb"},"inLanguage":"fa-IR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/delta-gas.com\/continuous-emission-monitoring-systems-cems\/"]}]},{"@type":"ImageObject","inLanguage":"fa-IR","@id":"https:\/\/delta-gas.com\/continuous-emission-monitoring-systems-cems\/#primaryimage","url":"https:\/\/delta-gas.com\/wp-content\/uploads\/2022\/08\/EMISSION-570x300-1.jpg","contentUrl":"https:\/\/delta-gas.com\/wp-content\/uploads\/2022\/08\/EMISSION-570x300-1.jpg","width":570,"height":300},{"@type":"BreadcrumbList","@id":"https:\/\/delta-gas.com\/continuous-emission-monitoring-systems-cems\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/delta-gas.com\/fa\/"},{"@type":"ListItem","position":2,"name":"\u0633\u06cc\u0633\u062a\u0645\u200c\u0647\u0627\u06cc \u067e\u0627\u06cc\u0634 \u0645\u062f\u0627\u0648\u0645 \u0622\u0644\u0627\u06cc\u0646\u062f\u0647\u200c\u0647\u0627 (CEMS)"}]},{"@type":"WebSite","@id":"https:\/\/delta-gas.com\/#website","url":"https:\/\/delta-gas.com\/","name":"Delta Gas Mobin Group","description":"Delta Gas Mobin Group is established in 2010 and recognized today as one of the","publisher":{"@id":"https:\/\/delta-gas.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/delta-gas.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fa-IR"},{"@type":"Organization","@id":"https:\/\/delta-gas.com\/#organization","name":"Delta Gas Mobin Group","url":"https:\/\/delta-gas.com\/","logo":{"@type":"ImageObject","inLanguage":"fa-IR","@id":"https:\/\/delta-gas.com\/#\/schema\/logo\/image\/","url":"https:\/\/delta-gas.com\/wp-content\/uploads\/2022\/08\/Delta-gas22.png","contentUrl":"https:\/\/delta-gas.com\/wp-content\/uploads\/2022\/08\/Delta-gas22.png","width":150,"height":45,"caption":"Delta Gas Mobin Group"},"image":{"@id":"https:\/\/delta-gas.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/delta-gas.com\/fa\/wp-json\/wp\/v2\/pages\/1204","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/delta-gas.com\/fa\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/delta-gas.com\/fa\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/delta-gas.com\/fa\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/delta-gas.com\/fa\/wp-json\/wp\/v2\/comments?post=1204"}],"version-history":[{"count":2,"href":"https:\/\/delta-gas.com\/fa\/wp-json\/wp\/v2\/pages\/1204\/revisions"}],"predecessor-version":[{"id":1206,"href":"https:\/\/delta-gas.com\/fa\/wp-json\/wp\/v2\/pages\/1204\/revisions\/1206"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/delta-gas.com\/fa\/wp-json\/wp\/v2\/media\/622"}],"wp:attachment":[{"href":"https:\/\/delta-gas.com\/fa\/wp-json\/wp\/v2\/media?parent=1204"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}